AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

The AMC300L AC multi-loop intelligent power collection and monitoring device is mainly used for full electrical parameter measurement of multiple loops and can be connected to up to 6 three-phase loops or 18 single-phase loops with current input at the same time. It can measure voltage and current, power, power factor and other parameters.

微信图片_20260730104417_383_62.jpg
               

Main Feature 

● Channel: 6 channel 3 phase or 18 channel 1 phase :

● Rated Voltage: AC 3×220V/380V

● Accurancy: Voltage and current level 0.5, active energy level 1

● RS485(MODBUS-RTU)

● Opening size: 88*88mm

 


Dimension

     

     
  •  

     


Parameter

Technical Parameter

Indicators

Input

Frequency

45~65Hz;

Voltage

Rated value: AC 3×220V/380V;

Overload: 1.2 times the rated value (continuous); 2 times the rated value/1 second;

Power consumption: ≤ 0.5VA (per circuit);

Current

Rated value: AC 100A;

Overload: 1.2 times the rated value (continuous); 10 times rated value/1 second;

Power consumption: ≤ 0.5VA (per circuit);

Function

Reserved pulse output

Output mode: optocoupler pulse with Open collector;

Communication

Modbus RTU protocol ; Baud 1200~38400

Switch-ing

input

4 dry contact inputs, 2 active (AC 220V input)

output

Output method: relay normally open contact output; Contact capacity: AC 250V/3A DC 30V/3A;

Temperature

Temperature: -20-100 ℃ (accuracy ± 2 ℃)

Measurement accuracy

Frequency 0.05Hz, voltage and current level 0.5, active energy level 1

Auxiliary power supply

AC/DC 85 to 265V; power consumption ≤ 10VA;

Security

 

power-frequency withstand voltage

>AC 2kV/1min;

insulation resistance

Input and output terminals to casing>100M Ω;

Environment

Working temperature:-20℃~+60℃;

Storage temperature:-40℃~+70℃;

Relative humidity:≤ 95% without condensation;

Altitude: ≤ 2500m;

Electromagnetic compatibility

Surge (impact) immunity test level 4;

Electrostatic discharge immunity test level 3

Electrical fast transient pulse group immunity test level 3

 


Wiring

 


Network

 


Application


Sıcak Ürün:% s

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Sorgu

Bizim için herhangi bir öneriniz veya sorunuz varsa. Lütfen bize ulaşın
*İsim
telefon
*e-posta
Adres
*İleti