ADL200 Series Single Phase Energy Meter

MID Certification 35mm DIN Rail Mounted

ADL200 din rail energy meter adopts DIN35mm din rail installation with LCD display. It can measure electric parameters and has energy pulse output, RS485 communication, which has the advantages of small size, high precision, good reliability and convenient installation.

ADL200
         

Main Feature 

● Rated Current: 10 (80) A

● Rated Voltage: AC 220V

● Active power、Voltage、Current、Power factor、Frequency

● Communication: RS485 (MODBUS-RTU)

● 8 digits LCD Display

● 35mm DIN Rail Installation

● MID Certificated

 


Overview




Parameter

Project

Performance parameter

Specification

Single phase

 

 
 
Input voltage

 

Reference voltage

AC 220V

Reference frequency

50Hz

Power consumption

<10VA

 

 

Input current


 

 

 

Basic current

10A

Maximum current

80A
Starting current
4‰Ib
Consumption
<4VA
 
Measurement performance

 


 

Accuracy of measuring

Class 1

Range of measuring
0~99999999kWh

 

Active pulse

 

Pulse width
80±20ms
Pulse constant
1000imp/kWh
 
 
 
Communication

 


 

 

Interface
RS485(A+、B-)
Connection mode

Shielded twisted pair conductors

Protocol

Modbus RTU

Strong current terminal torque
<1.8Nm
Clock accuracy
≤0.5s/d
 
Temperature range

 

Work temperature
-25℃~55℃
Storage temperature
-40℃~70℃
Relative humidity

≤95℅ (No condensation)

Altitude
<2000m

 


Wiring

 

 

 

① Enter-wire

② Brand

③ Panel

④ Up Button

⑤ Down Button

⑥ Pluse Output

⑦ Model

⑧ Set Button

⑨ Out-wire

 

1-phase 2-wire wiring diagram of ADL200

 


Network


Package

MINIMUM PACKAGE

 

 

MINIMUM PAKAGE

Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.5Kg

 

WHOLE BOX PAKAGE

 

Package dimensions(36 PCS)

450*240*250mm

Pakage Weight(36 PCS)

18.5kG

 

PRODUCT HS CODE

 

9028301400

 


FAQ

Q:The display power or energy count is inaccurate after the meter powered on.

 

A:Switch the meter display interface to the power (active power P, power factor λ) interface, and check whether the power display is negative or not.And whether the power factor is between 0.9-0.95, and then check whether the incoming and outgoing wires of the current signal wire are connected reversely (that is, the current The incoming wire must be the same as the incoming wire end of the meter), and consistent with the wiring diagram on the meter.

 


Q:It cannot communicate with the host computer normally after the instrument powered on.

 

A:1. The voltage value between the communication output A and B of the measuring instrument should be between +(4.4-4.5)V .

   2. Check whether the communication wiring method is correctly wired according to the wiring diagram (that is, the communication terminal A/B of the instrument must be connected with Corresponding to communication serial port A/B);

 

 


Product Application


Sıcak Ürün:% s

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Sorgu

Bizim için herhangi bir öneriniz veya sorunuz varsa. Lütfen bize ulaşın
*İsim
telefon
*e-posta
Adres
*İleti