Sıcak Ürün:% s
ADL200 din rail energy meter adopts DIN35mm din rail installation with LCD display. It can measure electric parameters and has energy pulse output, RS485 communication, which has the advantages of small size, high precision, good reliability and convenient installation.
Main Feature
● Rated Current: 10 (80) A
● Rated Voltage: AC 220V
● Active power、Voltage、Current、Power factor、Frequency
● Communication: RS485 (MODBUS-RTU)
● 8 digits LCD Display
● 35mm DIN Rail Installation
● MID Certificated
Overview


Parameter
|
Project |
Performance parameter |
|
|
Specification |
Single phase |
|
|
Input voltage
|
Reference voltage |
AC 220V |
|
Reference frequency
|
50Hz |
|
|
Power consumption
|
<10VA |
|
|
Input current
|
Basic current |
10A
|
|
Maximum current |
80A
|
|
|
Starting current
|
4‰Ib
|
|
|
Consumption
|
<4VA
|
|
|
Measurement performance
|
Accuracy of measuring
|
Class 1 |
|
Range of measuring
|
0~99999999kWh
|
|
|
Active pulse
|
Pulse width
|
80±20ms
|
|
Pulse constant
|
1000imp/kWh
|
|
|
Communication
|
Interface
|
RS485(A+、B-)
|
|
Connection mode
|
Shielded twisted pair conductors |
|
|
Protocol
|
Modbus RTU |
|
|
Strong current terminal torque
|
<1.8Nm
|
|
|
Clock accuracy
|
≤0.5s/d
|
|
|
Temperature range
|
Work temperature
|
-25℃~55℃
|
|
Storage temperature
|
-40℃~70℃
|
|
|
Relative humidity
|
≤95℅ (No condensation) |
|
|
Altitude
|
<2000m
|
|
Wiring
![]() |
① Enter-wire ② Brand ③ Panel ④ Up Button ⑤ Down Button ⑥ Pluse Output ⑦ Model ⑧ Set Button ⑨ Out-wire |

Network

Package
|
MINIMUM PACKAGE
|
![]() |
![]() |
![]() |
![]() |
|
MINIMUM PAKAGE |
Package dimensions(1 PC) 170*150*130mm |
Pakage Weight(1 PC) 0.5Kg |
||
|
WHOLE BOX PAKAGE
|
Package dimensions(36 PCS) 450*240*250mm |
Pakage Weight(36 PCS) 18.5kG |
||
|
PRODUCT HS CODE
|
9028301400 | |||
FAQ
Q:The display power or energy count is inaccurate after the meter powered on.
A:Switch the meter display interface to the power (active power P, power factor λ) interface, and check whether the power display is negative or not.And whether the power factor is between 0.9-0.95, and then check whether the incoming and outgoing wires of the current signal wire are connected reversely (that is, the current The incoming wire must be the same as the incoming wire end of the meter), and consistent with the wiring diagram on the meter.
Q:It cannot communicate with the host computer normally after the instrument powered on.
A:1. The voltage value between the communication output A and B of the measuring instrument should be between +(4.4-4.5)V .
2. Check whether the communication wiring method is correctly wired according to the wiring diagram (that is, the communication terminal A/B of the instrument must be connected with Corresponding to communication serial port A/B);
Product Application

Sıcak Ürün:% s

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.
Sorgu