ADW210 IoT Multi-Circuit Energy Meter

Up to 4 Channels 3 Phase Circuits

ADW210 series multi-loop power meter is mainly used for the measurement of all electric parameters of three-phase circuit. Colleagues can select the current input of the maximum four circuits. ADW2XX series products are connected by split core current transformer, easy to install on site, and realize remote wireless communication through wireless communication module.

ADW210.1.jpg
             

Main Feature 

● Rated Voltage: AC 3×220V/380V

● Rated Current: AC 5A, 100A, 400A, 600A (with external CTs)

● Active power、Voltage、Current、Power factor、Harmonics

● Communication: RS485 (Modbus-RTU)

● LCD Display

● 2~31st Harmonic Measurement

● CE Certified

 


Overview

               Main part dimension(L×W×H): 87.8*72*71.5mm

               35mm Din rail installation; Tolerance: ±1mm

                    Main part dimension(L×W×H): 87.8*36*71.5mm

                         35mm Din rail installation; Tolerance: ±1mm

 

Current Transformer

Matched with ADW2xx Series

 
Dimension(mm) Perforation size (mm)
W H D M N φ1 φ2
AKH-0.66/K-∅ 10N 27 44 32 25 36 10 9
AKH-0.66/K-∅ 16N 31 50 36 27 42 16 17
AKH-0.66/K-∅ 24N 39 71 46 36 52 24 23.5
AKH-0.66/K-∅ 36N 42.5 82 58 40 56 36 35

 

 

 

Picture of Current Transformer

 


Parameter

Project

Performance parameter

Specification

3 phase 3 wires, 3 phase 4 wires

Auxiliary power
AC/DC 85~265V;consumption≤10VA;
 
 
 
 
Input

 
 
 
 
Frequency
45~65Hz;
 
Voltage
 

 
AC 3×220V/380V;
Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s;
Power consumption:≤ 0.5VA;
 
Current

 
 
AC 5A、100A、400A、600A;(External opening transformer)
Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s;
Power consumption:≤ 0.5VA;
Measurement accuracy
Frequency 0.05Hz, voltage and current 0.5 level, active electric energy level 1, reactive electric energy level 2;
2-31 times harmonic accuracy: ± 1%;
Features
Pulse output
Output mode: optocoupler pulse with open collector;
Communication
RS485、Modbus-RTU;Baud rate 1200~38400;
 
Switching

 
input
Dry contact input、Built in power supply;
output
Output mode: Relay normally open contact output;
contact rating: AC 250V/3A DC 30V/3A;
Switching Module
Power
RJ45 interface、DC 12V、Power consumption≤1W;
Communication
RJ45 interface、Modbus-RTU;(Communication with the main Part)
Switching input 
Dry contact input、Built in power supply;
Switching output
Output mode:Relay normally open contact output;
Contact rating:AC 250V/3A DC 30V/3A;
Temperature and leakage module
Power
RJ45 interface、DC 12V、Power consumption≤1W
Communication
RJ45 interface、Modbus-RTU;(Communication with the main Part)
Temperature measurement
-20~100℃;
Leakage measurement
10~3000mA;
Measurement accuracy 
Temperature ±2℃、Leakage1.0%;
 
Safety
Power frequency withstand voltage
>AC 2kV/1min;
Insulation resistance
>100MΩ;
Environment
Working temperature:-20℃~+60℃;
Storage temperature:-40℃~+70℃;
Relative humidity:≤95% No condensation;
Altitude:≤2500m;
Electromagnetic compatibility 
Better than grade 3;

 


Wiring

 

 

① U / Pulse / DO / DI / Communication / Auxiliary Power Supply

② Brand

③ Panel

④ Model Number

⑤ CH1, CH2, CH3, CH4 for current / extension module interface

⑥ Button

⑦ Infrared Status

⑧ Pulse Output Light

 

3 Phase 3 Wire

 

3 Phase 4 Wire

 


Network

 

Package

MINIMUM PACKAGE

 

 

MINIMUM PAKAGE

Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.5Kg

 

WHOLE BOX PAKAGE

 

Package dimensions(36 PCS)

450*240*250mm

Pakage Weight(36 PCS)

18.5kG

 

PRODUCT HS CODE

 

9028301400

 


FAQ

Q: What should I do if I have no display when I power on the meter?

A: Check whether the power supply voltage is within the operating voltage range.

 

Q: What to do if the meter voltage,current,electric energy and other readings are not correct?

A: Check whether the voltage to current ratio is set correctly, whether the connection mode is set as actual, and whether the voltage transformer and current transformer are in good condition.

 

Q: What if the meter power or power factor is incorrect?

A: Check whether the connection mode, voltage and current phase sequence are correct, and cable connections are correct.

 

Q: What to do if the instrument communication is abnormal?

A: Please check whether the address, baud rate and parity bit in the communication. Settings are consistent with the host computer, whether the RS485 converter is normal, and whether the wiring is correct. If the check is correct, the resistance above 120 ohm can be connected in parallel at the communication end.

 


Product Application


Sıcak Ürün:% s

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Sorgu

Bizim için herhangi bir öneriniz veya sorunuz varsa. Lütfen bize ulaşın
*İsim
telefon
*e-posta
Adres
*İleti