AGF-AE-D Solar Inverter Energy Meter

UL Certification Single Phase Paired with 2 External CTs

In a single inverter system, the meter is connected directly to the inverter. If your inverter has a built-in revenue grade meter (RGM; the inverter is referred to a revenue grade inverter), you can connect an external meter on the same bus as the RGM.

AGF-AE-D.1.jpg
           

Main Feature 

● Rated Current: AC 200A

● Rated Voltage: AC 120V/208V, 240(88%~110%)

● Active power、Voltage、Current、Power factor、Harmonics

● Communication: RS485 (Modbus-RTU)

● Dimension of CT: 70.5mm×54.5mm×39mm (H×W×D) 

● 35mm DIN Rail Installation

● UL Certified

 


Overview

     

 

 

 


Parameter

Meter Electrical Service Units 
Rated Voltage-Line to N 120 V
Rated Voltage-Line to Line 208/240  V
Extended Voltage Range  88%~110%  
AC Frequency  60 Hz
Grids Supported L1/L2/N/PE   
Power Consumption  1.2 W
Communication
Meter Communication Interfaces 
RS 485  
Response Time
≤1 S 
Meter Accuracy 
Rated RMS current 
200 A 
1%-100% of CT Current
±1  %
Current Transformers
Number of Supplied Current Transformers 2 
 
Dimensions 70.5×54.5×39 (H×W×D) 
mm
Standard Compliance 
Safety UL1741 
 
Installation Specifications
Dimensions(H×W×D)  54.1×87.8×52
mm 
Weight
0.2 
kg
Operating Temperature Range 
-30~55
℃ 
Relative Humidity (noncondensing)
5 - 90 
%
Mounting Type
DIN-Rail,35mm 
 

 

 


Wiring



 

 

 

① Brand / Model

 

② Panel

 

③ Indictor Lights

 

④ Reset Button

 

⑤ Current Transformer

 

 

 


Network

 


Package

MINIMUM PACKAGE

 

 

MINIMUM PAKAGE

Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.5Kg

 

WHOLE BOX PAKAGE

 

Package dimensions(36 PCS)

450*240*250mm

Pakage Weight(36 PCS)

18.5kG

 

PRODUCT HS CODE

 

9028301400

 


FAQ

Q: What should I do if I have no display when I power on the meter?

A: Check whether the power supply voltage is within the operating voltage range.

 

Q: What to do if the meter voltage,current,electric energy and other readings are not correct?

A: Check whether the voltage to current ratio is set correctly, whether the connection mode is set as actual, and whether the voltage transformer and current transformer are in good condition.

 

Q: What if the meter power or power factor is incorrect?

A: Check whether the connection mode, voltage and current phase sequence are correct, and cable connections are correct.

 

Q: What to do if the instrument communication is abnormal?

A: Please check whether the address, baud rate and parity bit in the communication. Settings are consistent with the host computer, whether the RS485 converter is normal, and whether the wiring is correct. If the check is correct, the resistance above 120 ohm can be connected in parallel at the communication end.


Product Application


Sıcak Ürün:% s

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Sorgu

Bizim için herhangi bir öneriniz veya sorunuz varsa. Lütfen bize ulaşın
*İsim
telefon
*e-posta
Adres
*İleti