AKH-0.66K-Φ Series Split Core Current Transformer

20/40/100mA Split Core CT

Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment. The appearance is nice and the installation and wiring are convenient. AKH-0.66/K-Φ series split current transformers are mainly used in reconstructing projects of urban and rural power grids. Product has the advantages of small size, high accuracy, strong load capacity, easy installation, etc. They save the manpower, material resources and financial resources and improve the efficiency of users.

AKH-0.66-K mA.png
             

Main Feature 

● Rated operation voltage: AC 0.66kV

● Rated frequency: 50-60Hz

● Rated secondary current: X/20mA, 40mA, 100mA

● Accuracy: Class 0.5

● Suitable for electricity renovation project


Overview

 


 


Parameter

Specification
Rated current ratio (A)
Precision degree
Straight through tums
Max. cable outer diameter (mm)
0.5
1
K-Φ10
 
5A/1.25mA
10
 
1
 
Φ10
 
(10-20)A/5mA
10
 
1
(40-60)A/20mA
10
 
1
K-Φ16
(20-50)A/10mA
10
 
1
 
Φ16
 
(40-100)A/20mA
10
 
1
100A/40mA
10
 
1
K-Φ24
(60-200)A/20mA
10
 
1
 
Φ24
 
(100-250)A/40mA
10
 
1
400A/100mA
10
 
1
K-Φ36
(200-400)A/20mA
10   1
Φ36
 
(300-600)A/100mA
10   1
400A/40mA
10
 
1
600A/75mA
10
 
1
K-Φ50
(600~800)A/100mA 10   1 Φ50

 


Installation

 

 


Package

MINIMUM PACKAGE

 

 

MINIMUM PAKAGE

Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.5Kg

 

WHOLE BOX PAKAGE

 

Package dimensions(36 PCS)

450*240*250mm

Pakage Weight(36 PCS)

18.5kG

 

PRODUCT HS CODE

 

9028301400

 


Product Application


Sıcak Ürün:% s

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Sorgu

Bizim için herhangi bir öneriniz veya sorunuz varsa. Lütfen bize ulaşın
*İsim
telefon
*e-posta
Adres
*İleti