AMC16-DETT Base Station DC Energy Meter for 5G Tower is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering.
The meter could measure6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.have the functions of telemetering, teleindication, teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction.
Main Feature
● DC rated Voltage: 1 channel: -48VDC
● DC rated Current: 6 channels hall sensors - total 200A/5V
● Active power、Voltage、Current、Power factor、Frequency
● Communication: RS485 (Modbus-RTU)
● 35mm DIN Rail Installation
● Designed for base stations
Overview
Parameter
|
Technical parameters
|
Indicators
|
|
|
Input
|
DC rated voltage
|
1 channel: -48VDC
|
|
DC current
|
6 channels hall sensors: total 200A/5V, China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V
|
|
|
Commercial power monitoring
|
1 channel: 0-5VDC
|
|
|
Overload capacity
|
Voltage:1.2times continued, 2 times continued 1s;
Current: 1.2 times continued, 10 times continued 1s.
|
|
|
Accuracy (superposition hall sensors)
|
1%In≤I≤10%In error±2.5%; I>10%In error±2%
|
|
|
Measurement resolution
|
Voltage output accuracy 0.01V; current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh
|
|
|
Functions
|
Basic function
|
Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED
indicator display;485 communication
|
|
Metering function
|
Start current: under rated voltage, when the load current value of the meter doesn’t exceed 1% of the max. current, the meter starts. Shunt running current: when there is no current in the current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change
|
|
|
Alarm function
|
DC voltage output low alarm,DC voltage output high alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm, memory failure alarm, AC input power failure alarm
|
|
|
Timing function
|
support broadcast timing, could remote timing to the meter through RS485 communication
|
|
|
Communication
|
Single channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.
Communication protocol: standard or custmized
|
|
|
Hall sensor power supply
|
Power supply output:+12V/100Ma, -12V/50mA
|
|
|
Clock accuracy
|
≤0.5S/d(23℃), ≤1S/d(-20℃-60℃)
|
|
|
Auxiliary power supply
|
Voltage range
|
-40V~-60VDC
|
|
Power consumption
|
Whole device≤2W( no hall power supply output)
|
|
|
Storage
|
It has the storage function of historical power data and historical alarm information, and the memory is 2MB
|
|
|
Insulation resistance
|
≥40MΩ
|
|
|
Environment
|
Temperature
|
Working : -20℃~+60℃; storage:-40℃~+70℃
|
|
Humidity
|
≤98% no condensation, no corrosive gas place
|
|
|
Altitude
|
≤4000m
|
|
|
Protection level
|
IP20
|
|
|
Material flame retardent
|
Terminal glow wire temperature 960℃±10℃ ,shell glow wire temperature 6500℃±15℃
|
|
|
Installation
|
Standard 35mm din rail
|
|
|
Lightning protection
|
Voltage input (differential mode)
|
Peak value 5kA
|
|
Auxiliary power supply (differential mode)
|
Peak value 5kA
|
|
Wiring
Network
Package
|
MINIMUM PACKAGE
|
![]() |
![]() |
![]() |
![]() |
|
MINIMUM PAKAGE |
Package dimensions(1 PC) 170*150*130mm |
Pakage Weight(1 PC) 0.5Kg |
||
|
WHOLE BOX PAKAGE
|
Package dimensions(36 PCS) 450*240*250mm |
Pakage Weight(36 PCS) 18.5kG |
||
|
PRODUCT HS CODE
|
9028301400 | |||
FAQ
Q: What should I do if I have no display when I power on the meter?
A: Check whether the power supply voltage is within the operating voltage range.
Q: What to do if the meter voltage, current, electric energy and other readings are not correct?
A: Check whether the voltage to current ratio is set correctly, whether the connection mode is set as actual, and whether the voltage transformer and current transformer are in good condition.
Q: What if the meter power or power factor is incorrect?
A: Check whether the connection mode, voltage and current phase sequence are correct, and cable connections are correct.
Q: What to do if the instrument communication is abnormal?
A: Please check whether the address, baud rate and parity bit in the communication. Settings are consistent with the host computer, whether the RS485 converter is normal, and whether the wiring is correct. If the check is correct, the resistance above 120 ohm can be connected in parallel at the communication end.
Product Application

Sıcak Ürün:% s

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.