AMC16L-DETT Base Station DC Energy Meter

LCD display 6 Circuits DC Energy Measurement

AMC16-DETT Base Station DC Energy Meter for 5G Tower is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. 

The meter could measure6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.have the functions of telemetering, teleindication, teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction.

AMC16L-DETT-1.jpg
               

Main Feature 

● DC rated Voltage: 1 channel: -48VDC

● DC rated Current: 6 channels hall sensors - total 200A/5V

● Active power、Voltage、Current、Power factor、Frequency

● Communication: RS485 (Modbus-RTU)

● LCD display

● 35mm DIN Rail Installation

● Designed for base stations

 


Overview

     

 

 


Parameter

Technical parameters
Indicators
Input
DC rated voltage 
1 channel: -48VDC 
DC current 
6 channels hall sensors: total 200A/5V, China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V
Commercial power monitoring
1 channel: 0-5VDC 
Overload capacity
Voltage:1.2times continued, 2 times continued 1s;
Current: 1.2 times continued, 10 times continued 1s.
Accuracy (superposition hall sensors)
1%In≤I≤10%In error±2.5%; I>10%In error±2%
Measurement resolution 
Voltage output accuracy 0.01V; current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh
Functions
Basic function 
Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED
indicator display;485 communication 
Metering function 
Start current: under rated voltage, when the load current value of the meter doesn’t exceed 1% of the max. current, the meter starts. Shunt running current: when there is no current in the current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change 
Alarm function
DC voltage output low alarm,DC voltage output high alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm, memory failure alarm, AC input power failure alarm
Timing function 
support broadcast timing, could remote timing to the meter through RS485 communication
Communication
Single channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.
Communication protocol: standard or custmized 
Hall sensor power supply
Power supply output:+12V/100Ma, -12V/50mA 
Clock accuracy 
≤0.5S/d(23℃), ≤1S/d(-20℃-60℃)
Auxiliary power supply 
Voltage range 
-40V~-60VDC 
Power consumption
Whole device≤2W( no hall power supply output)
Storage 
It has the storage function of historical power data and historical alarm information, and the memory is 2MB
Insulation resistance 
≥40MΩ 
Environment
Temperature
Working : -20℃~+60℃; storage:-40℃~+70℃ 
Humidity
≤98% no condensation, no corrosive gas place
Altitude
≤4000m
Protection level 
IP20
Material flame retardent 
Terminal glow wire temperature 960℃±10℃ ,shell glow wire temperature 6500℃±15℃
Installation
Standard 35mm din rail
Lightning protection
Voltage input (differential mode)
Peak value 5kA 
Auxiliary power supply (differential mode)
Peak value 5kA

 

 


Wiring

 

 


Network


 


Package

MINIMUM PACKAGE

 

 

MINIMUM PAKAGE

Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.5Kg

 

WHOLE BOX PAKAGE

 

Package dimensions(36 PCS)

450*240*250mm

Pakage Weight(36 PCS)

18.5kG

 

PRODUCT HS CODE

 

9028301400

 


FAQ

Q: What should I do if I have no display when I power on the meter?

A: Check whether the power supply voltage is within the operating voltage range.

Q: What to do if the meter voltage, current, electric energy and other readings are not correct?

A: Check whether the voltage to current ratio is set correctly, whether the connection mode is set as actual, and whether the voltage transformer and current transformer are in good condition.

Q: What if the meter power or power factor is incorrect?

A: Check whether the connection mode, voltage and current phase sequence are correct, and cable connections are correct.

Q: What to do if the instrument communication is abnormal?

A: Please check whether the address, baud rate and parity bit in the communication. Settings are consistent with the host computer, whether the RS485 converter is normal, and whether the wiring is correct. If the check is correct, the resistance above 120 ohm can be connected in parallel at the communication end.

 


Product Application


Sıcak Ürün:% s

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Sorgu

Bizim için herhangi bir öneriniz veya sorunuz varsa. Lütfen bize ulaşın
*İsim
telefon
*e-posta
Adres
*İleti