AMC72L-E4/KC Multifunction Power Meter

Three Phase Panel Mounted Energy Meter

AMC series meters adopt AC sampling technology, which can measure the current, voltage, power, power factor and electric energy parameters in the power grid separately. It can set the magnification through the panel membrane switch. The meters have RS485 communication interface, adopt Modbus protocol; also can convert the power signal into a standard DC analog signal.

 

未标题-3.png
             

Main Feature 

● Rated Current: AC 1A, 5A

● Rated Voltage: AC 3×57.7V/100V (100V), 3×220V/380V (400V)

● Active power、Voltage、Current、Power factor、Harmonics

● Communication: RS485 (MODBUS-RTU)

● LCD Display

● 2~31st Harmonic Measurement

● IEC Certificated

 


Overview


 


Parameter

Technical parameters
Value

 

Input

Connection

3 phase 4 wire, 3 phase 3 wire

Frequency

45~65Hz

 

Voltage

Rating: AC 100V, 400V

Overload: 1.2 times rated value(continuous); 2 times rated value(1 second)

Power consumption: < 0.5VA

 

Current

Rating: AC 1A, 5A

Overload: 1.2 times rated value(continuous); 10 times rated value (1 second)

Power consumption:< 0.5VA

 

Output 

Energy

Pulse width: 80±20ms

Pulse constant: 10000, 40000, 160000 imp/kWh

Communication

RS485 (Modbus-RTU)

Function

 

Switching input 

2 channels or 4 channels passive contact input mode

Switching output 

Output mode:2 channel relay NO contact output

Analog output 

Contact capacity: 3A/30V DC, 3A/250V AC 0~5V,0~20mA,4~20mA programmable

Accuracy

Frequency:0.05Hz,current,voltage:class 0.2, reactive power:class 1.0,reactive energy:class 1.0,other:class 0.5,2~31st harmonic :±1%

Auxiliary power supply

AC/DC 85~265V

Power consumption

≤10VA 

Insulation resistance 

 ≥100MΩ 

Environment 

 

 

Temperature

Operating: -10°C~+55°C Storage: -25°C ~+75°C 

Humidity

≤93%(no condensation) 

Altitude

≤2500m 

 


Wiring

 

 


Network


Package

MINIMUM PACKAGE

 

 

MINIMUM PAKAGE

Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.5Kg

 

WHOLE BOX PAKAGE

 

Package dimensions(36 PCS)

450*240*250mm

Pakage Weight(36 PCS)

18.5kG

 

PRODUCT HS CODE

 

9028301400

 


FAQ

Q: No display on power?

A: Check whether the supply voltage is within the operating voltage range.

 

Q: Incorrect reading of voltage,current,electricty,etc?

A: Checking that the voltage/current ratio setting are correct;

Checking whether the wiring mode setting is consistent with the actual situation;

Checking whether the voltage transformer and current transformer are in good condition.

 

Q: Abnormal communication?

A: Check whether the adress,baud rate,check bits in the communication;

Setting are consistent with the host computer;

Check whether the RS485 converter is normal;

Check the connection is corrent if the resistor above 120 ohm is connected in parallel at the communication end.

 

 


Product Application


Sıcak Ürün:% s

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Sorgu

Bizim için herhangi bir öneriniz veya sorunuz varsa. Lütfen bize ulaşın
*İsim
telefon
*e-posta
Adres
*İleti