Sıcak Ürün:% s
Main Feature
● Rated Current: AC 1A, 5A
● Rated Voltage: AC 100V、400V
● Active power、Voltage、Current、Power factor、Frequency
● Communication: RS485 (MODBUS-RTU)
● True RMS Measurements
Overview
![]() |
![]() |
|
|
|
![]() |
|
Parameter
|
Technical Parameters
|
Index
|
|
|
Input
|
Connetction
|
3 phase 3 wire, 3 phase 4 wire |
|
Frequency
|
45~65Hz
|
|
|
Voltage
|
Rated value:AC 100V、400V
|
|
|
Overload: 1.2 times rated value(continuous); 2 times rated value(1 second)
|
||
|
Power consumption: < 0.2VA (per channel) |
||
|
Current |
Rated value: AC 1A, 5A |
|
|
Overload: 1.2 times rated value(continuous); 10 times rated value(1 second) |
||
|
Power consumption: < 0.2VA (per channel) |
||
| Output | Electric energy |
Output mode: 2 channel open-collector photo coupler pulse |
| Pulse constant: 10000 , 40000, 160000 imp/kWh |
||
| Communication | RS485port, Modbus -RTU protocol | |
| Display |
LED or LCD display, set multiplying power, alarm, switching indication at will; For 1 channel analog, display related programmable setting |
|
| Function |
Switching input |
2 channel or 4 channel passive dry contact input mode |
| Switching output |
Output mode: 1, 2 or 4 channel Output, 0 - 20mA,4 - 20mA programmable | |
| Contact capacity- 1A/30VDC 1A/250VAC |
||
| Analog output |
Output mode: 1, 2 or 4 channel Output, 0 - 20mA,4 - 20mA programmable | |
| Load capacity ≤500Ω | ||
| Accuracy class | Frequency 0.05Hz, reactive electric energy 1 class, others 0.5 class | |
| Power supply | DC100~350V;AV 85~265V; (In order to instrument wiring shall prevail ) |
|
| Power consumption <5VA | ||
| Security | Equipment withstand voltage= power supply, voltage input circuit 2kVAC;power supply,current circuit 2.5kV/ 1min(RMS) Insulation resistance- input, output end to housing > 100MΩ | |
| Environment |
Temperature |
Work: - 10°C~+55°C Storage: -25°C ~+75°C |
| Humidity |
≤93%RH Non-condensing | |
| Altitude |
≤2500m | |
Wiring

Network

Package
|
MINIMUM PACKAGE
|
![]() |
![]() |
![]() |
![]() |
|
MINIMUM PAKAGE |
Package dimensions(1 PC) 170*150*130mm |
Pakage Weight(1 PC) 0.5Kg |
||
|
WHOLE BOX PAKAGE
|
Package dimensions(36 PCS) 450*240*250mm |
Pakage Weight(36 PCS) 18.5kG |
||
|
PRODUCT HS CODE
|
9028301400 | |||
FAQ
Q: CAN THE RATIO OF AMC72-AI BE SETTED BY MYSELF?
A: Yes, it can be set by yourselves.
Q: CAN THE VOLTAGE AND CURRENT INTERFACE BE DISPLAYED FIRST AFTER PZ72-DE IS POWERED ON? IS THIS SET UP BEFORE LEAVING THE FACTORY?
A: Voltage and current cannot be displayed at the same time. Now voltage, current and energy are displayed in turn.
Q: DOES ACREL HAVE A DIGITAL METER THAT DISPLAYS PRESSURE, TORQUE, AND SPEED?
A: Reverse display meter, PZ72-DI. PZ96B-Dl is also available.
Q: PZ72-DI ARE EQUIPPED WITH HALL SENSOR. CAN THE METER DIRECTLY SUPPLY POWER TO HALL SENSOR? STILL NEED EXTERNAL POWER SUPPLY?
A: Need external power supply.
Q: 0-1500R, 4-20MA, CAN I USE PZ96B?
A: PZ96B-DI, PZ72-DI can be used as a tachometer or an ammeter.
Q: IS THERE A MODULE THAT CAN DIRECTLY CONVERT ANALOG TO DIGITAL? 4-20MA ANALOG SIGNAL IS CONVERTED TO DIGITAL SIGNAL (SWITCH SIGNAL), THAT IS, INPUT AI AND OUTPUT DO?
A: PZ72-DI/K is to detect 4-20mA, alarm output.
Product Application

Sıcak Ürün:% s

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.
Sorgu